Spara och bevara* bibliographic database

Homb, Anders and Uvslokk, Sivert (2012) Energieffektive bevaringsverdige vinduer - Målinger og beregninger. Technical Report. SINTEF Byggforsk.

Full text not available from this repository.
Official URL: http://www.riksantikvaren.no/filestore/Endelignors...

Abstract

SINTEF has carried out a project for the Cultural Heritage Board and Enova to document the effects of energy-efficient conservation on windows. The project had the following contents: - Measurements of U-value - Calculations of the U-value with accurate and simplified method - Measurements of air tightness and drying ability - Measurement and evaluation of sound insulation - Calculation of heat balance The measurements show that one can achieve U-values between 1.5 and 1.6 W/m² K for an older window with inner frame with single glass with hard coating. With a two-layer insulating the new frame can achieve U-value below 1.0 W / m² K.

Item Type: Monograph (Technical Report)
Uncontrolled Keywords: Windows; U-values; Measurments; Heat loss
Subjects: ?? build ??
Svenska, danska, norska > Byggnadens klimatskal > Fönster och dörrar
Depositing User: Anna Samuelsson
Date Deposited: 18 Jul 2012 11:59
Last Modified: 04 Apr 2017 09:09
URI: http://eprints.sparaochbevara.se/id/eprint/675

Actions (login required)

View Item View Item